HULK POWER HP02W004S1 Manuel d'utilisation et d'entretien Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 11
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
BREAK-IN PROCEDURES & OPERATION
LOCATION OF THE AIR COMPRESSOR
Your compressor comes almost completely assembled, the air filter must be installed. Operate the air compressor in a dry, clean, cool, well
ventilated area. The air compressor pump and case are designed to allow for proper cooling. Clean or blow off dust or dirt that collects on the
air compressor. A clean air compressor runs cooler and provides longer service. The ventilation openings on your air compressor are necessary
to maintain proper operating temperature. Do not place rags or other containers on or near these openings.
ADDITIONAL REGULATORS AND CONTROLS
Since the air tank pressure is usually greater than that which is needed, a regulator is employed to control the air pressure ahead of any
individual driven device. Separate air transformers which combine the function of air regulation, moisture and dirt removal should be used where
applicable.
BREAK-IN PROCEDURES
NOTE: SERIOUS DAMAGE MAY RESULT IF THE FOLLOWING BREAK-IN INSTRUCTIONS ARE NOT CLOSELY FOLLOWED. THIS
PROCEDURE IS REQUIRED BEFORE THE AIR COMPRESSOR CAN BE PUT INTO SERVICE, AFTER REPLACING THE CHECK VALVE,
AND WHEN THE PISTON OR THE CYLINDER SLEEVE IS REPLACED.
OPERATING PROCEDURES
Preparation for use:
1. Before attaching an air hose or accessories, make sure the OFF lever is set to “OFF” and the air regulator is closed. Once this is done,
you can now attach a hose or an accessory.
WARNING: Too much air pressure causes a hazardous risk of bursting. Check the manufacturer's maximum pressure rating for air tools and
accessories. The regulator outlet pressure must never exceed the maximum pressure rating of the tool being used.
3. Turn the “ON/AUTO OFF” lever to “ON/AUTO” and allow tank pressure to build. Motor will stop when tank pressure reaches “Cut-Out”
pressure.
4. Open the regulator by turning it clockwise. Adjust the regulator to the correct pressure setting. The compressor is ready for use.
5. Always operate the air compressor in well ventilated areas; free of gasoline or other solvent vapors. Do not operate the compressor near the
spray area.
After Use:
6. Set the “ON/AUTO OFF” lever to “OFF”.
7. Turn the regulator counterclockwise to set the outlet pressure to zero.
8. Disconnect the air tool or accessory.
9. Pull ring on safety valve (B) Fig. 5, allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.
10. Drain water from air tank. Turn drain valve (A) Fig. 4, counterclockwise to open.
WARNING!: WATER WILL CONDENSE IN THE AIR TANK. IF NOT DRAINED REGULARLY, WATER WILL CORRODE AND WEAKEN THE
AIR TANK CAUSING A RISK OF AIR TANK RUPTURE.
NOTE: If drain valve is plugged, pull ring on safety valve (B) Fig. 5, and hold until air pressure has been released. The valve can then be removed,
cleaned, and reinstalled.
11. After the water has been completely drained, turn drain valve to close. The air compressor can now be stored.
6
A. Fill crankcase with oil as described in “Changing Oil” in the maintenance section on the following page.
B. Set the pressure switch lever to the “OFF” position.
C. Plug the power cord into the correct 110V branch circuit receptacle.
D. Fully open the drain valve (A) Fig. 4, by turning it counterclockwise, to prevent air pressure build-up in the tank.
E. Move the pressure switch lever to “ON/AUTO”. The compressor will start.
F. Run the compressor for 15 minutes. Make sure the drain valve is open and there is no tank pressure build-up by watching the
tank pressure gauge.
G. After 15 minutes, close the drain valve by turning clockwise. The air receiver will fill to “Cut-Out” pressure and the motor
will stop. The compressor is now ready for use.
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11

Commentaires sur ces manuels

Pas de commentaire